2u Rack Mount UPS Double Conversion Online UPS with Epo
HomeHome > Products > Rack Online UPS > 2u Rack Mount UPS Double Conversion Online UPS with Epo
2u Rack Mount UPS Double Conversion Online UPS with Epo

2u Rack Mount UPS Double Conversion Online UPS with Epo

2U Rack Mount UPS Double Conversion Online UPS with EPO UPS Model: High Frequency Online UPS Rack Mount Star Series RM 1
Basic Info
Model NO. Rack Mount Star Series
Phase Single Phase
Type On-line
Protection Short Circuit
Application Industry
Classification Lighting/Power
Standby Time Long-acting Machine
Standby UPS Sine Wave Output UPS
Output Capacity Large Type
Equipment Mode Decentralized
Brand Upsen
Power Factor 0.97
Operating Temperature 0 ~ 40°c
Current Crest Ratio 3:1
Communications RS-232 Serial Interface
Transport Package Wooden Box
Specification CE, ISO, RoHS
Trademark UPSEN
Origin China
HS Code 8504402000
Production Capacity 50, 000PCS/Month
Product Description
2U Rack Mount UPS Double Conversion Online UPS with EPO
UPS Model: High Frequency Online UPS Rack Mount Star Series RM 1K-10KVA(1Ph in/1Ph out)

Quick View:
1:Rack Mounted 19 Inch and 2U 3U 5U height design
2:Rack UPS with ECO and advanced ECO mode for energy saving
3:N+X parallel redundancy available for 6K and up models
4:Rack Mountable Online UPS with Emergency Power Off Function (EPO)

Key Features:
1:Smart RS232 communication with monitoring software
2:Strong antijamming capability
3:User-friendly and easy-shift LCD display
4:Rack Mounted 19 Inch and 2U 3U 5U height design
5:Programmable power management outlets
6:Intelligent battery charger, durable and worry-saving
7:ECO and advanced ECO mode for energy saving
8:Emergency Power Off Function (EPO)
9:Stable performance for advanced digital circuit system
10:Humanization bypass output, can be adjustable.
11:Optional extension battery pack
12:Rack mount 19"design to save space
13:Network/fax/modem surge protection
14:Transfer time 0ms, no interruption from AC state to DC state

Technical Specification

Rack Mount Star Series RM1K-10K
ModelRM1KRM2KRM3KRM1KLRM2KLRM3KLRM6KLRM10KL
InputPhaseSingle Phase with Ground
Nominal Voltage110/115//120Vac or 220/230/240Vac220/230/240Vac
Voltage Range60-138VAC or 115 ~ 300VAC176 ~ 276VAC
Frequency Range46 ~ 54Hz(default), user adjustable within 40~60Hz46 ~ 54Hz
Power Factor0.970.98
ConnectionIEC320-10A inletIEC320-16A inletIEC320-10A inletIEC320-16A inletTerminal Block
OutputPhaseSingle Phase
Voltage110/115/120Vac or 220/230/240VAC ± 2%110/115/120Vac or 220/230/240VAC± 1%
Frequency46~54Hz or 50Hz ± 0.2Hz (Line mode)46~54Hz (Line mode)
50Hz ± 0.2Hz ( Battery mode)50Hz ± 0.05Hz ( Battery mode)
WaveformPure Sine Wave
Power Factor0.7/0.8 Optional
Overload Capability108%~150% for 30 sec., 150% for 300 ms
105%~130% for 10 min.,
130% for 1 min.

Current Crest Ratio
3:1
ConnectionsIEC320 -10A * 4
IEC320-10A and
Terminal Block

IEC320 -10A * 4

IEC320-10A and
Terminal Block

IEC320-10A * 4 and
Terminal Block

Bypass
Automatic Transferon overload and UPS failure
Before UPS Power-onDefault "NO", user adjustable to "YES"Yes
Voltage Range 80~264VAC (Default), user adjustable within 80~286VAC176 ~ 261VAC
Transfer Time0 ms; less than 4 ms from inverter to bypass and vice versaZero
LED /LCD indicators
Load level / Battery level, Battery , Utility Power,
Inverter, Bypass, Overload, Fault

Audible Alarm
Bypass, On battery mode, Battery low, Overload, Fault
CommunicationsRS-232 Serial Interface
Intelligent Slot;

OPTIONS: WEBPOWER SNMP/WEB card,
AS400 card or WinPower CMC)

Network Surge Protection
RJ45 I/O port available for network or Fax/Modem
EnvironmentalOperating Temperature0 ~ 40°C
Operating Humidity20 ~ 90% non-condensing
Main UnitNet Weight (Kg)16.310.311.29.111.512.318.320.3
Dimensions (W x D x H) mm482 x 420 x 88 (2U)
482 x 420 x 88 (2U) or
(3U Internal Batteries)

482 x 420 x 88 (2U)
482.6 x 600 x 130 (3U)
Battery PackTypeInternal BatteriesExternal Battery Pack
Nominal DC Voltage24/36VDC48/72VDC72/96VDC24/36VDC48/72VDC72/96VDC192/240VDC

Battery Numbers
& Capacity

2/3Pcs *12V7.2Ah
4/6Pcs *12V7.2Ah6/8Pcs *12V7.2Ah
Depending on the capacity of
external battery packs

Backup Time (Full load)
5 min7min (with 1 BP)5 min (with 1 BP)
Recharge Time5hrs to 90%5hrs to 90%5hrs to 90%
Charging Current (Max.)1.0A1.0A1.0A8A±1A4.2A
Charging Voltage41.1Vdc±0.6V110Vdc±0.4V41.1Vdc±0.6V110Vdc±0.4V274Vdc±1%V
Net Weight (Kg) ---25.325.3------------
Dimensions (W x D x H) mm ---482 x 420 x88 (2U)482 x 420 x88 (2U) --------- ---

2u Rack Mount UPS Double Conversion Online UPS with Epo

2u Rack Mount UPS Double Conversion Online UPS with Epo

2u Rack Mount UPS Double Conversion Online UPS with Epo