Basic Info
Model NO. | Star Series 10K-60KVA |
Phase | Three Phase |
Type | On-line |
Protection | Unbalanced Loads |
Application | Communication |
Classification | Lighting/Power |
Standby Time | Standard Machine |
Standby UPS | Sine Wave Output UPS |
Output Capacity | Large Type |
Equipment Mode | Centralized Model |
Brand | Upsen |
Transport Package | Cartons |
Specification | 797*438*176mm[4U] |
Trademark | upsen |
Origin | Shenzheng, China |
HS Code | 8504402000 |
Production Capacity | 50000PCS/Month |
Product Description
Key Features:- • True double-conversion
- • LCD screen auto-rotation with Rack position (only for 10K-20K models)
- • DSP technology guarantees high performance
- • Output power factor 1
- • Active power factor correction in all phases
- • 50Hz/60Hz frequency converter mode
- • ECO mode operation for energy saving (ECO)
- • Emergency power off function (EPO)
- • Generator compatible
- • Supports dual AC inputs
- • 3-stage extendable charging design for optimized battery performance
- • Adjustable battery numbers for long-run model
- • Parallel operation with commom battery
- • Optional isolation transformer offers full isolation and complete common mode noise rejection
Technical Specification
MODEL 33RM 10KL 33RM 15KL 33RM 20KL 33RM 30KL 33RM 40KL 33RM 60KL PHASE 3-phase in / 3-phase out CAPACITY 10KVA/10KW 15KVA/15KW 20KVA/20KW 30KVA/30KW 40KVA/40KW 60KVA/60KW PARALLEL CAPABILITY 4 INPUT Nominal Voltage 3 x 400 VAC (3Ph+N) Voltage Range 190-520 VAC (3-phase) @ 50% load , 305-478 VAC (3-phase) @ 100% load Frequency Range 46~54 Hz or 56~64Hz Power Factor >= 0.99 @ 100% load OUTPUT Output Voltage 3 * 360 / 380 / 400 / 415 VAC (3Ph+N) AC Voltage Regulation (Batt. Mode) ± 1% Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz Current Crest Ratio 3:1 (max.) Harmonic Distortion <= 2 % THD (Linear Load) , <= 5 % THD (Non-linear Load) Transfer Time AC mode to Battery mode zero Inverter to Bypass zero Waveform (Batt. Mode) Pure Sine Wave Overload AC Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Battery Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately EFFICIENCY AC Mode 95.5% ECO Mode 98.5% Battery Mode 94.5% BATTERY Battery Type Depending on the applications Numbers 20 pcs 32~40 pcs (Adjustable) Charging Current (max.) 1A ~ 12A (Adjustable) 1A ~ 16A (Adjustable) 1A ~ 18A (Adjustable) Charging Voltage +/-13.65 VDC x N (N=10) +/-13.65V x N (N=16~20) ALARM Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously sounding PHYSICAL Dimension, D * W * H (mm) 680*438*133 [3U] 797*438*176 [4U] Net Weight (kgs) 26 28 28 40 40 45 ENVIRONMENT Operation Temperture 0-40°C Operation Humidity <95% and non-condersing Noise Level Less than 62dB @ 1 Meter Less than 65dB @ 1 Meter Less than 65dB @ 1 Meter Less than 65dB @ 1 Meter Less than 70dB @ 1 Meter MANAGEMENT Smart RS-232/USB Supports Windows® family, Linux and MAC Optional SNMP Power management from SNMP manager and web browser *When output voltage is set as 3 x 360VAC, the output power of the unit will be de-rated to 90%. *Product specifications are subject to change without further notice