10K-60kVA True Double-Conversion Online Rack Mount UPS
HomeHome > Products > Rack Online UPS > 10K-60kVA True Double-Conversion Online Rack Mount UPS
10K-60kVA True Double-Conversion Online Rack Mount UPS

10K-60kVA True Double-Conversion Online Rack Mount UPS

Key Features:
Basic Info
Model NO. Star Series 10K-60KVA
Phase Three Phase
Type On-line
Protection Unbalanced Loads
Application Communication
Classification Lighting/Power
Standby Time Standard Machine
Standby UPS Sine Wave Output UPS
Output Capacity Large Type
Equipment Mode Centralized Model
Brand Upsen
Transport Package Cartons
Specification 797*438*176mm[4U]
Trademark upsen
Origin Shenzheng, China
HS Code 8504402000
Production Capacity 50000PCS/Month
Product Description
Key Features:
  • • True double-conversion
  • • LCD screen auto-rotation with Rack position (only for 10K-20K models)
  • • DSP technology guarantees high performance
  • • Output power factor 1
  • • Active power factor correction in all phases
  • • 50Hz/60Hz frequency converter mode
  • • ECO mode operation for energy saving (ECO)
  • • Emergency power off function (EPO)
  • • Generator compatible
  • • Supports dual AC inputs
  • • 3-stage extendable charging design for optimized battery performance
  • • Adjustable battery numbers for long-run model
  • • Parallel operation with commom battery
  • • Optional isolation transformer offers full isolation and complete common mode noise rejection

    Technical Specification

    MODEL33RM 10KL 33RM 15KL 33RM 20KL 33RM 30KL 33RM 40KL 33RM 60KL
    PHASE3-phase in / 3-phase out
    CAPACITY10KVA/10KW15KVA/15KW20KVA/20KW30KVA/30KW40KVA/40KW60KVA/60KW
    PARALLEL CAPABILITY4
    INPUT
    Nominal Voltage3 x 400 VAC (3Ph+N)
    Voltage Range190-520 VAC (3-phase) @ 50% load , 305-478 VAC (3-phase) @ 100% load
    Frequency Range46~54 Hz or 56~64Hz
    Power Factor>= 0.99 @ 100% load
    OUTPUT
    Output Voltage3 * 360 / 380 / 400 / 415 VAC (3Ph+N)
    AC Voltage Regulation (Batt. Mode)± 1%
    Frequency Range (Synchronized Range)46~54Hz or 56~64Hz
    Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
    Current Crest Ratio3:1 (max.)
    Harmonic Distortion<= 2 % THD (Linear Load) , <= 5 % THD (Non-linear Load)
    Transfer TimeAC mode to Battery modezero
    Inverter to Bypasszero
    Waveform (Batt. Mode)Pure Sine Wave
    OverloadAC Mode100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately
    Battery Mode100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately
    EFFICIENCY
    AC Mode95.5%
    ECO Mode98.5%
    Battery Mode94.5%
    BATTERY
    Battery TypeDepending on the applications
    Numbers20 pcs32~40 pcs (Adjustable)
    Charging Current (max.)1A ~ 12A (Adjustable)1A ~ 16A (Adjustable)1A ~ 18A (Adjustable)
    Charging Voltage+/-13.65 VDC x N (N=10)+/-13.65V x N (N=16~20)
    ALARM
    Battery ModeSounding every 4 seconds
    Low BatterySounding every second
    OverloadSounding twice every second
    FaultContinuously sounding
    PHYSICAL
    Dimension, D * W * H (mm)680*438*133 [3U]797*438*176 [4U]
    Net Weight (kgs)262828404045
    ENVIRONMENT
    Operation Temperture0-40°C
    Operation Humidity<95% and non-condersing
    Noise LevelLess than 62dB @ 1 MeterLess than 65dB @ 1 MeterLess than 65dB @ 1 MeterLess than 65dB @ 1 MeterLess than 70dB @ 1 Meter
    MANAGEMENT
    Smart RS-232/USBSupports Windows® family, Linux and MAC
    Optional SNMPPower management from SNMP manager and web browser
    *When output voltage is set as 3 x 360VAC, the output power of the unit will be de-rated to 90%.
    *Product specifications are subject to change without further notice

10K-60kVA True Double-Conversion Online Rack Mount UPS

10K-60kVA True Double-Conversion Online Rack Mount UPS

10K-60kVA True Double-Conversion Online Rack Mount UPS

10K-60kVA True Double-Conversion Online Rack Mount UPS

10K-60kVA True Double-Conversion Online Rack Mount UPS